| 230V | |
| Scheme: ETA-EMI PSU | ![]() |
| 230V | |
No LAMBDA levelAverage noise output 48.47 dB(A), above the 45 dB(A) limit of the lowest LAMBDA level (Standard). |
Scheme: LAMBDA PSU |
Outside Validation Scope

| Load range | Points | Efficiency 230V | PF 230V |
|---|---|---|---|
| 0-<20 % | 297 | 88.34% | 0.934 |
| 20-<40 % | 322 | 94.05% | 0.985 |
| 40-<60 % | 320 | 93.86% | 0.992 |
| 60-<80 % | 318 | 92.86% | 0.995 |
| 80-100 % | 324 | 91.55% | 0.997 |
| 70-100 % (High-Load) | 482 | 91.89% | 0.996 |
| All (published average) | 1581 | 92.19% | 0.981 |
Informational. Not part of the ETA or LAMBDA rating.
| Load range | Noise 230V avg (loudest) | Fan off 230V |
|---|---|---|
| 0-<20 % | 26.0 (31.2) | 0% |
| 20-<40 % | 27.3 (31.2) | 0% |
| 40-<60 % | 32.1 (41.9) | 0% |
| 60-<80 % | 47.4 (50.8) | 0% |
| 80-100 % | 54.6 (56.5) | 0% |
| 70-100 % (High-Load) | 53.4 (56.5) | 0% |
| All (published average) | 48.5 (56.5) | 0% |
Informational. Not part of the ETA or LAMBDA rating.
| Load | Normal ambient fan · noise · intake | High ambient fan · noise · intake | Noise change |
|---|---|---|---|
| 10% | 426 RPM · 9.7 dB(A) · 30.5 °C | 447 RPM · 11.8 dB(A) · 40.5 °C | +2.1 dB(A) |
| 20% | 429 RPM · 11.1 dB(A) · 30.2 °C | 478 RPM · 11.1 dB(A) · 40.6 °C | +0.0 dB(A) |
| 50% | 846 RPM · 24.2 dB(A) · 30.2 °C | 1385 RPM · 38.4 dB(A) · 42.2 °C | +14.2 dB(A) |
| 100% | 2793 RPM · 56.5 dB(A) · 31.0 °C | 2917 RPM · 57.1 dB(A) · 47.0 °C | +0.6 dB(A) |
Informational. Not part of the ETA or LAMBDA rating.