| Average Efficiency (>1450 load combinations) | 91.189% |
| Average Noise Output (>1450 Load Combinations) | 30.29dBA |
| Average PF (>1450 Load Combinations) | 0.943 |
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 62.853% |
| Standby Power Consumption | 0.0988W |
| 12V Ripple (Full Load) | 40.01mV |
| 5V Ripple (Full Load) | 21.74mV |
| 3.3V Ripple (Full Load) | 23.11mV |
| 5VSB Ripple (Full Load) | 17.55mV |
| 12V Load Regulation | 0.18% |
| 5V Load Regulation | 1.89% |
| 3.3V Load Regulation | 3.28% |
| 5VSB Load Regulation | 4.54% |
| Inrush Current | 72.240A |
| 12V Transient Response (200%) | 11.38V |
| 5V Transient Response (200%) | 4.937V |
| 3.3V Transient Response (200%) | 3.173V |
| 5VSB Transient Response (200%) | 4.942V |
| Hold-Up Time & PWR_OK Signal | 18.90ms |
| AC Loss to PWR_OK Hold Up Time | 14.50ms |
| PWR_OK Inactive to DC Loss Delay | 4.40ms |
| PSU Timings: T1 (20% / 100%) | 100.0ms | 100.0ms |
| PSU Timings: T3 (20% / 100%) | 123.0ms | 124.0ms |
| 12V OCP (28.1°C / 41.4°C) | 75.900A (121.44%), 11.973V — shut down | 75.700A (121.12%), 11.969V — shut down |
| 5V OCP (28.1°C / 41.4°C) | 28.700A (143.50%), 5.075V — shut down | 27.800A (139.00%), 5.078V — shut down |
| 3.3V OCP (28.1°C / 41.4°C) | 29.300A (146.50%), 3.293V — shut down | 28.600A (143.00%), 3.292V — shut down |
| 5VSB OCP (28.1°C / 41.4°C) | 4.900A (163.33%), 4.915V — shut down | 4.700A (156.67%), 4.919V — shut down |
| OPP (29.77°C / 42.66°C) | 120.25% | 119.26% |