| Average Efficiency (>1450 load combinations) | 92.001% |
| Average Noise Output (>1450 Load Combinations) | 28.70dBA |
| Average PF (>1450 Load Combinations) | 0.954 |
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 70.187% |
| Standby Power Consumption | 0.1168W |
| 12V Ripple (Full Load) | 32.17mV |
| 5V Ripple (Full Load) | 24.78mV |
| 3.3V Ripple (Full Load) | 27.87mV |
| 5VSB Ripple (Full Load) | 20.49mV |
| 12V Load Regulation | 0.34% |
| 5V Load Regulation | 0.58% |
| 3.3V Load Regulation | 1.36% |
| 5VSB Load Regulation | 4.66% |
| Inrush Current | 43.680A |
| 12V Transient Response (200%) | 11.29V |
| 5V Transient Response (200%) | 4.913V |
| 3.3V Transient Response (200%) | 3.142V |
| 5VSB Transient Response (200%) | 4.916V |
| Hold-Up Time & PWR_OK Signal | 17.90ms |
| AC Loss to PWR_OK Hold Up Time | 11.40ms |
| PWR_OK Inactive to DC Loss Delay | 6.50ms |
| PSU Timings: T1 (20% / 100%) | 60.0ms | 64.0ms |
| PSU Timings: T3 (20% / 100%) | 122.0ms | 121.0ms |
| 12V OCP (28.5°C / 42.1°C) | 101.200A (121.49%), 11.998V — shut down | 101.200A (121.49%), 12.002V — shut down |
| 5V OCP (28.5°C / 42.1°C) | 28.700A (143.50%), 5.025V — shut down | 28.000A (140.00%), 5.026V — shut down |
| 3.3V OCP (28.5°C / 42.1°C) | 29.600A (148.00%), 3.253V — shut down | 29.600A (148.00%), 3.264V — shut down |
| 5VSB OCP (28.5°C / 42.1°C) | 4.900A (163.33%), 4.925V — shut down | 4.900A (163.33%), 4.921V — shut down |
| OPP (31.16°C / 41.34°C) | 120.80% | 120.55% |