| Average Efficiency (>1450 load combinations) | 91.761% |
| Average Noise Output (>1450 Load Combinations) | 21.72dBA |
| Average PF (>1450 Load Combinations) | 0.945 |
| Efficiency With 10W (≤500W) or 2% (>500W) Load | 71.942% |
| Standby Power Consumption | 0.1499W |
| 12V Ripple (Full Load) | 40.45mV |
| 5V Ripple (Full Load) | 27.19mV |
| 3.3V Ripple (Full Load) | 28.58mV |
| 5VSB Ripple (Full Load) | 24.00mV |
| 12V Load Regulation | 1.00% |
| 5V Load Regulation | 0.46% |
| 3.3V Load Regulation | 0.37% |
| 5VSB Load Regulation | 3.95% |
| Inrush Current | 67.580A |
| 12V Transient Response (200%) | 11.29V |
| 5V Transient Response (200%) | 4.936V |
| 3.3V Transient Response (200%) | 3.200V |
| 5VSB Transient Response (200%) | 4.959V |
| Hold-Up Time & PWR_OK Signal | 19.80ms |
| AC Loss to PWR_OK Hold Up Time | 16.50ms |
| PWR_OK Inactive to DC Loss Delay | 3.30ms |
| PSU Timings: T1 (20% / 100%) | 104.0ms | 102.0ms |
| PSU Timings: T3 (20% / 100%) | 118.0ms | 117.0ms |
| 12V OCP (27.9°C / 41.7°C) | 95.800A (115.01%), 11.969V — shut down | 96.100A (115.37%), 11.963V — shut down |
| 5V OCP (27.9°C / 41.7°C) | 24.200A (121.00%), 5.169V — shut down | 24.200A (121.00%), 5.176V — shut down |
| 3.3V OCP (27.9°C / 41.7°C) | 23.900A (119.50%), 3.456V — shut down | 23.800A (119.00%), 3.464V — shut down |
| 5VSB OCP (27.9°C / 41.7°C) | 4.000A (133.33%), 4.872V — shut down | 4.000A (133.33%), 4.877V — shut down |
| OPP (28.51°C / 41.40°C) | 125.54% | 125.54% |