SATA (460mm) / 4-pin Molex (+120mm+120mm) / FDD (+120mm)
1
1 / 2 / 1
18-20AWG
No
AC Power Cord (1380mm) - C13 coupler
1
1
18AWG
-
Test Results
Temperature & Compliance Info
Temperature Range (°C /°F)
28-30 / 82.4-86
ErP Lot 3/6 Ready
✓
(EU) No 617/2013 Compliance
✗
Performance Summary
效率評比
BRONZE
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
82.734%
Average Noise Output (>1450 Load Combinations)
31.85dBA
Average PF (>1450 Load Combinations)
0.991
Efficiency With 10W (≤500W) or 2% (>500W) Load
55.611%
Standby Power Consumption
0.0452W
12V Ripple (Full Load)
53.24mV
5V Ripple (Full Load)
19.85mV
3.3V Ripple (Full Load)
21.63mV
5VSB Ripple (Full Load)
25.49mV
12V Load Regulation
1.41%
5V Load Regulation
1.11%
3.3V Load Regulation
2.34%
5VSB Load Regulation
3.11%
Inrush Current
43.288A
效率評比
BRONZE
噪音評比
Standard++
Average Efficiency (>1450 load combinations)
85.151%
Average Noise Output (>1450 Load Combinations)
31.77dBA
Average PF (>1450 Load Combinations)
0.967
Efficiency With 10W (≤500W) or 2% (>500W) Load
0.000%
Standby Power Consumption
0.1033W
12V Ripple (Full Load)
66.69mV
5V Ripple (Full Load)
26.95mV
3.3V Ripple (Full Load)
21.40mV
5VSB Ripple (Full Load)
30.98mV
12V Load Regulation
1.41%
5V Load Regulation
1.34%
3.3V Load Regulation
2.28%
5VSB Load Regulation
3.07%
Inrush Current
43.109A
12V Transient Response (150%)
0.00V
5V Transient Response (150%)
V
3.3V Transient Response (150%)
V
5VSB Transient Response (150%)
V
Hold-Up Time & Power Ok Signal
19.60ms
AC Loss to PWR_OK Hold Up Time
15.40ms
PWR_OK Inactive to DC Loss Delay
4.20ms
PSU Timings: T1 (20% / 100%)
0.0ms
0.0ms
PSU Timings: T3 (20% / 100%)
0.0ms
0.0ms
OPP (0.00°C / 0.00°C)
0.00%
0.00%
Hold-Up Time & Power Ok Signal
Hold-Up Time (ms)
19.6
AC Loss to PWR_OK Hold Up Time (ms)
15.4
PWR_OK Inactive to DC Loss Delay (ms)
4.2
待機電源消耗
Tables
Graphs
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
INFO
This graph is generated by the PPA Standby Power Analysis software which takes full control of the power analyzer during the whole procedure. This application features all of the EN50564 & IEC62301 test limits for standby power software testing.
Efficiency Graph
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
INFO
This graph depicts the PSU`s efficiency throughout its entire operational range. For the generation of the efficiency and noise graphs we set our loaders to auto mode through our custom-made software before trying thousands of possible load combinations.
Noise Graph
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
INFO
The PSU`s noise in its entire operational range and under 30-32 °C ambient is depicted in this graph. The X axis represents the load on the +12V rail(s) while the Y axis is the load on the minor rails.
Conducted Emissions EN55032 & CISPR 32
Indicative Performance
Efficiency under high ambient temperature
INFO
The PSU`s efficiency under high ambient temperatures with 115V and 230V input. For this graph the results of the 10-110% load regulation table are used.
5VSB Efficiency
INFO
This graph depicts the efficiency levels of the 5VSB rail with 115V and 230V input.
5VSB Efficiency (ERP LOT 3/6 & CEC)
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.226
72.903%
0.046
5.029V
0.310
115.03V
2
0.090A
0.453
77.702%
0.085
5.029V
0.583
115.03V
3
0.550A
2.761
80.897%
0.299
5.020V
3.413
115.03V
4
1.000A
5.010
81.016%
0.366
5.010V
6.184
115.03V
5
1.500A
7.499
80.634%
0.402
5.000V
9.300
115.03V
6
3.000A
14.900
77.030%
0.450
4.967V
19.343
115.03V
Test #
5VSB
DC/AC (Watts)
Efficiency
PF/AC Volts
1
0.045A
0.226
62.259%
0.017
5.029V
0.363
230.18V
2
0.090A
0.453
69.907%
0.030
5.029V
0.648
230.18V
3
0.550A
2.761
77.950%
0.144
5.020V
3.542
230.18V
4
1.000A
5.010
79.853%
0.216
5.010V
6.274
230.18V
5
1.500A
7.499
80.263%
0.268
4.999V
9.343
230.17V
6
3.000A
14.893
79.744%
0.342
4.965V
18.676
230.18V
Protection Features
Supplementary Tests (For Reference)
Typical Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.902A
1.992A
1.954A
1.001A
44.725
76.102%
715
16.8
35.35°C
0.970
12.163V
5.018V
3.375V
4.995V
58.770
42.16°C
115.04V
2
4.809A
2.992A
2.939A
1.205A
89.220
82.473%
744
17.7
35.91°C
0.987
12.131V
5.009V
3.366V
4.981V
108.181
43.27°C
115.04V
3
8.127A
3.488A
3.422A
1.409A
134.362
84.351%
852
20.8
36.06°C
0.992
12.104V
5.017V
3.359V
4.968V
159.290
44.86°C
115.04V
4
11.448A
3.979A
3.937A
1.614A
179.590
84.938%
943
23.5
36.71°C
0.988
12.089V
5.027V
3.351V
4.957V
211.437
46.49°C
115.04V
5
14.435A
4.979A
4.936A
1.821A
224.896
84.740%
1124
28.2
37.16°C
0.989
12.082V
5.020V
3.342V
4.943V
265.394
47.69°C
115.04V
6
17.364A
5.987A
5.939A
2.029A
269.426
84.257%
1280
32.1
37.51°C
0.991
12.072V
5.013V
3.333V
4.929V
319.766
48.91°C
115.04V
7
20.368A
6.993A
6.947A
2.239A
314.725
83.547%
1470
35.0
38.80°C
0.993
12.059V
5.006V
3.325V
4.914V
376.703
51.11°C
115.04V
8
23.377A
8.006A
7.962A
2.451A
360.035
82.741%
1605
37.5
38.90°C
0.994
12.047V
4.997V
3.316V
4.898V
435.136
52.34°C
115.04V
9
26.835A
8.499A
8.464A
2.455A
404.937
81.834%
1782
40.2
39.38°C
0.994
12.015V
5.002V
3.308V
4.889V
494.829
54.21°C
115.04V
10
30.025A
8.996A
9.002A
3.084A
449.767
80.695%
1897
42.6
39.74°C
0.995
11.992V
5.003V
3.299V
4.865V
557.369
55.95°C
115.03V
11
33.885A
8.972A
9.022A
3.089A
494.565
79.514%
1990
42.8
40.14°C
0.996
11.948V
5.016V
3.292V
4.857V
621.987
58.30°C
115.03V
CL1
0.130A
13.000A
13.000A
0.000A
103.069
75.799%
1375
33.6
37.76°C
0.987
12.644V
4.461V
3.341V
4.969V
135.976
48.08°C
115.05V
CL2
35.998A
1.000A
1.000A
1.000A
435.565
81.387%
1707
39.5
39.45°C
0.995
11.723V
5.298V
3.322V
4.940V
535.177
55.57°C
115.04V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
Temps (In/Out)
PF/AC Volts
1
1.906A
1.993A
1.954A
1.001A
44.766
77.610%
711
16.8
35.09°C
0.818
12.160V
5.016V
3.374V
4.994V
57.681
41.82°C
230.19V
2
4.811A
2.995A
2.938A
1.205A
89.232
84.076%
734
17.3
35.94°C
0.914
12.128V
5.007V
3.365V
4.980V
106.133
43.22°C
230.18V
3
8.129A
3.488A
3.421A
1.410A
134.353
86.217%
821
20.3
36.24°C
0.949
12.101V
5.015V
3.358V
4.967V
155.832
44.37°C
230.19V
4
11.448A
3.980A
3.936A
1.615A
179.562
86.949%
961
23.7
36.61°C
0.963
12.087V
5.025V
3.350V
4.956V
206.513
45.84°C
230.18V
5
14.433A
4.981A
4.936A
1.821A
224.843
86.967%
1104
28.0
36.93°C
0.971
12.080V
5.019V
3.341V
4.943V
258.537
47.04°C
230.19V
6
17.364A
5.987A
5.939A
2.030A
269.370
86.684%
1251
31.1
37.30°C
0.976
12.069V
5.012V
3.333V
4.928V
310.750
48.25°C
230.19V
7
20.368A
6.998A
6.948A
2.240A
314.668
86.212%
1426
34.0
37.81°C
0.980
12.056V
5.003V
3.324V
4.913V
364.995
49.63°C
230.18V
8
23.371A
8.012A
7.962A
2.450A
359.959
85.645%
1587
37.4
38.01°C
0.982
12.047V
4.994V
3.315V
4.899V
420.294
50.33°C
230.16V
9
26.837A
8.501A
8.467A
2.456A
404.895
85.018%
1790
40.2
38.39°C
0.984
12.013V
5.000V
3.306V
4.888V
476.249
52.76°C
230.16V
10
30.031A
9.001A
9.004A
3.085A
449.754
84.244%
1917
42.6
39.14°C
0.986
11.989V
5.001V
3.298V
4.863V
533.872
54.73°C
230.17V
11
33.893A
8.978A
9.024A
3.091A
494.573
83.496%
1988
42.8
40.22°C
0.987
11.945V
5.014V
3.291V
4.855V
592.332
56.77°C
230.17V
CL1
0.132A
13.002A
12.998A
0.000A
103.045
77.375%
1387
33.7
36.88°C
0.937
12.645V
4.457V
3.341V
4.968V
133.176
47.72°C
230.18V
CL2
35.998A
1.002A
0.999A
1.000A
435.353
84.650%
1772
40.1
39.12°C
0.985
11.717V
5.299V
3.321V
4.937V
514.299
54.60°C
230.17V
The results above are not used in the certification process
Light Load Tests
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.172A
0.489A
0.472A
0.199A
19.347
66.952%
677
15.5
0.922
12.175V
5.078V
3.382V
5.021V
28.897
115.04V
2
2.431A
0.988A
0.972A
0.399A
39.765
76.585%
683
15.9
0.967
12.130V
5.053V
3.378V
5.013V
51.923
115.04V
3
3.623A
1.486A
1.450A
0.600A
59.306
80.235%
693
16.2
0.977
12.122V
5.043V
3.374V
5.004V
73.915
115.04V
4
4.883A
1.985A
1.955A
0.801A
79.744
82.189%
719
16.8
0.982
12.115V
5.036V
3.370V
4.995V
97.025
115.04V
The results above are not used in the certification process
Test #
12V
5V
3.3V
5VSB
DC/AC (Watts)
Efficiency
Fan Speed (RPM)
PSU Noise (dB[A])
PF/AC Volts
1
1.182A
0.492A
0.472A
0.199A
19.479
68.271%
667
15.2
0.637
12.171V
5.077V
3.382V
5.019V
28.532
230.20V
2
2.440A
0.989A
0.977A
0.399A
39.883
77.913%
674
15.5
0.796
12.126V
5.052V
3.377V
5.012V
51.189
230.18V
3
3.632A
1.484A
1.451A
0.600A
59.390
81.684%
684
16.0
0.862
12.118V
5.042V
3.373V
5.002V
72.707
230.19V
4
4.890A
1.986A
1.955A
0.801A
79.808
83.909%
708
16.8
0.904
12.111V
5.035V
3.369V
4.993V
95.113
230.19V
The results above are not used in the certification process
Ripple Measurements
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.2 mV
6.5 mV
8.7 mV
12.3 mV
Pass
20% Load
13.4 mV
7.5 mV
9.6 mV
16.4 mV
Pass
30% Load
15.4 mV
8.9 mV
10.3 mV
15.1 mV
Pass
40% Load
19.0 mV
10.0 mV
11.0 mV
17.6 mV
Pass
50% Load
23.1 mV
11.8 mV
12.5 mV
18.7 mV
Pass
60% Load
34.7 mV
15.9 mV
14.4 mV
19.4 mV
Pass
70% Load
35.6 mV
15.3 mV
15.4 mV
19.7 mV
Pass
80% Load
38.3 mV
16.1 mV
18.7 mV
22.2 mV
Pass
90% Load
46.3 mV
18.2 mV
20.3 mV
22.1 mV
Pass
100% Load
53.2 mV
19.9 mV
21.6 mV
25.5 mV
Pass
110% Load
58.7 mV
21.0 mV
23.2 mV
26.1 mV
Pass
Crossload 1
21.6 mV
37.6 mV
17.5 mV
14.2 mV
Pass
Crossload 2
60.7 mV
18.3 mV
19.0 mV
21.7 mV
Pass
The results above are not used in the certification process
Test
12V
5V
3.3V
5VSB
Pass/Fail
10% Load
12.4 mV
5.9 mV
8.6 mV
11.4 mV
Pass
20% Load
13.9 mV
7.5 mV
9.4 mV
14.3 mV
Pass
30% Load
17.3 mV
8.7 mV
9.8 mV
13.8 mV
Pass
40% Load
20.1 mV
10.2 mV
10.8 mV
15.5 mV
Pass
50% Load
22.7 mV
10.6 mV
12.2 mV
17.3 mV
Pass
60% Load
30.2 mV
14.3 mV
13.7 mV
16.9 mV
Pass
70% Load
35.5 mV
15.5 mV
15.0 mV
17.8 mV
Pass
80% Load
38.3 mV
15.8 mV
18.1 mV
19.0 mV
Pass
90% Load
43.9 mV
17.6 mV
19.8 mV
22.7 mV
Pass
100% Load
66.7 mV
27.0 mV
21.4 mV
31.0 mV
Pass
110% Load
76.9 mV
29.8 mV
23.1 mV
33.7 mV
Pass
Crossload 1
22.1 mV
55.7 mV
17.9 mV
13.1 mV
Fail
Crossload 2
74.1 mV
26.2 mV
18.8 mV
20.6 mV
Pass
The results above are not used in the certification process