| Noise Levels (115V/230V Input) | Noise Requirements (1) |
|---|---|
| A++ | <15 dB(A) |
| A+ | ≥15 dB(A) & <20 dB(A) |
| A | ≥20 dB(A) & <25 dB(A) |
| A- | ≥25 dB(A) & <30 dB(A) |
| Standard ++ | ≥30 dB(A) & <35 dB(A) |
| Standard + | ≥35 dB(A) & <40 dB(A) |
| Standard | ≥40 dB(A) & <45 dB(A) |
The LAMBDA figure is the energy average of the noise over all the measured load combinations of the certification sweep. It is what the grade is based on and it does not change. A single average can hide how a power supply behaves at different loads, so each desktop PSU evaluation page also shows, where its measured data allows and for information only:
These figures are calculated from the measured load combinations of the certification sweep, and a figure is shown only when its five ranges add up to the average of the whole sweep. They are informational: they never change the ETA or LAMBDA grade, the score or any published average.
Redundant server PSUs have the efficiency and power factor ranges on their evaluation pages too; for them the ranges start at 2 % of the rated output, as in the Redundant Server PSU Test Protocol (Rev 1.3), section "Load-range results (informational)".
Two certified desktop units at 230 V input (names withheld). Their average noise is within 0.5 dB(A) of each other, so LAMBDA sees them alike, yet their High-Load Index differs by 4.6 dB(A).
| At 230 V input | Unit A | Unit B |
|---|---|---|
| Rated output | 650 W | 1000 W |
| Average noise (LAMBDA), dB(A) | 22.2 | 22.7 |
| High-Load Index (70-100 % load), dB(A) | 22.6 | 27.2 |
| Loudest point at 70-100 % load, dB(A) | 29.0 | 31.0 |
| Fan stopped, share of load points | 0 % | 17 % |
The full load-range results of these two units, with efficiency and power factor, are on their evaluation pages (section "Noise by load range"): Unit A · Unit B